34
IQAN-MC2 Technical Overview
Appendix A
Instruction book, IQAN-MC2
Power driver - PWMOUT
Number of PWMOUT 8 dual outputs
PWMOUT range 0% to 95%
PWMOUT resolution 0.1 %
Dither frequency, F
DITH
25 - 38, 40, 42, 43, 45, 48, 50, 53, 56, 59, 63, 67 Hz
71, 77, 83, 90, 100, 111, 125, 167, 200, 250, 333 Hz
Power driver voltage drop typ. 0.9 V @ 1.5 A load
Leakage current in off state <2 mA
Maximum load 2 A
Maximum allowable load inductance
1.0 A
1.5 A
500 mH
200 mH
Protection overload, SCB, SCG
Diagnostics no
Overload threshold typ. 2.5 A
DOUT (on/off output) power driver
Number of DOUT
high side
low side
8 (configuration may reduce number)
16 (configuration may reduce number)
Maximum load
DOUT-A to DOUT-H (high side)
DOUT-I to DOUT-X (low side)
2.0 A
2.0 A
Power driver voltage drop
DOUT-A to DOUT-H (high side)
DOUT-I to DOUT-X (low side)
typ. 0.3V @ 1.5 A load
typ. 0.6V @ 1.5 A load
Leakage current in off-state
DOUT-A to DOUT-H (high side)
DOUT-I to DOUT-X (low side)
< 1 mA
< 100 uA
Maximum allowable load inductance
1.0 A
1.5 A
500 mH
200 mH
Protection
Overload threshold (high side)
Overload threshold (low side)
typ. 2.5 A
typ. 5 A
Diagnostics
DOUT-A to DOUT-H (high side)
DOUT-I to DOUT-X (low side)
no
no
CAN
Parameter Remark
Number of CAN buses 2
CAN specification 2.0A and 2.0B
CAN speed 125 kbit to 500 kbit
Protection SCB, SCG
I/O
T
A
= +25 °C (unless otherwise specified)
Parameter Remark