Installation 
K-MT1-8_EN_08—2014  25 
Installing the electrical connection 
 
 
Warning against electrical voltage 
Only qualified specialist personnel may carry out work on the electrical 
system! 
Installing the supply cable 
The components of the dryer have been connected to the control cabinet at the 
factory. You only need to connect the control cabinet to the electrical supply 
cable.   
The switchbox is provided with a connector where electrical power must be 
connected. 
►  Ensure that the cross-section of the electrical supply cable corresponds to 
the power rating of the dryer and the electrical voltage provided by the 
customer. 
►  Make the electrical supply cable to the dryer voltage-free.  
►  Secure the electrical supply cable to the dryer against switch-on. 
►  Undo bolt (1) on the connector and 
withdraw connector with seal from the 
switchbox. 
 
►  Use a suitable tool to remove the 
terminal block from the connection 
box. 
►  Undo the PG union and pull the cable 
through the aperture (3). The 
exposed phase ends should not be 
longer than 35 mm max. 
 
►  Now make the cable connection as 
follows:  
—  Earth
 
to terminal PE  
—  L1 to terminal 1  
—  N to terminal 2 
Terminal 3 is not used. 
 
Connect electrical cable to device 
adapter 
►  Fit terminal block into the connector and use bolt to remount the connector 
with seal on the switchbox. 
►  In all phases the dryer must be protected against short circuits by means of 
fuses. 
►  In order to relief cable strain, re-tighten the PG union.