Emergency shutdown 
30  K-MT1-8_EN_08—2014 
Display  Explanation 
2  215 
Default display: The figure to the left indicates the current 
processing step; the figure to the right shows the remaining 
time in seconds. 
In this example, step 2 is being completed, whereby there are 
215 seconds remaining. 
SEr. 
After 8000 operating hours, "SEr." (service) is displayed for 
periods of 1 minute, alternating with the default display.  
Notify the service personnel of the manufacturer, as a routine 
service is now due. 
– 25 
With the dewpoint-sensing control option, the display shows the 
currently measured dewpoint instead of the default data. The 
range of display is -100 °C (-148 °F) to +20 °C (68 °F). 
If the measured dewpoint exceeds the preset alarm limit (5 °C 
(41 °F) above the switchover value), the displayed dewpoint 
value is flashing. 
With the optional dewpoint-sensing control, the following error messages might 
be displayed: 
Display  Cause 
+20  
  Upper measuring range limit exceeded 
999 
  Dewpoint sensor defective 
sens 
  Dewpoint sensor not powered 
  Cable defective or disconnected 
  Sensor defective 
or 
–999 
LED Economy cycle (4) 
This LED is only relevant in units that are equipped with the optional dewpoint-
sensing control. The diode lights up when the dryer is switched on and in the 
standby phase and no regeneration air is required. 
Emergency shutdown   
To emergency shut-down the dryer heed to the following instructions: 
►  Close shut off valves upstream and downstream of the dryer (if applicable) 
►  Disconnect the electrical power supply (i.e. by switching the ON/Off switch to 
0).  
  The dryer is now off-line. 
►  If applicable, depressurise the dryer now. 
Before re-commissioning the dryer ensure that the emergency situation has been 
solved and that the dryer is not damaged.  
Never comission a damaged dryer!