Annex with technical documentation
K-MT1-8_EN_082014 55
Technical data
Operating Range
Site Selection
frost-free indoor installation in a non-hazardous environment
Ambient temperature
1,5 to 50 °C (24,7 to 122 °F)
Compressed air inlet temperature
20 to 50 °C (68 to 122 °F)
Max. operating overpressure
16 bar
e
Min. operating pressure
5 bar
e
Medium
Compressed air and gaseous nitrogen
Fluid group acc. to 97/23/EG
2
Electrical connection
Mains voltage, standard
230 V, 50-60 Hz
Alternative voltage
115 V, 50-60 Hz and 24 V DC
Protection class
IP 65
Please heed to the type plate and the enclosed wiring diagram!
Performance data
Model
Volumetric
flow
1
in m3/h
Nominal
pipe size
Upstream
filter
Downstream
filter
Nominal
Pressure in bar
e
Nominal
temperature °C
K-MT 1
8
1/4
GL2XL
GL2ZLH
16
50
K-MT 2
15
1/4
GL2XL
GL2ZLH
16
50
K-MT 3
25
1/4
GL2XL
GL2ZLH
16
50
K-MT 4
35
1/4
GL2XL
GL2ZLH
16
50
K-MT 6
56
1/2
GL5XLD
GL5ZLDH
16
50
K-MT 7
72
1/2
GL5XLD
GL5ZLDH
16
50
K-MT 8
86
3/4
GL7XLD
GL7ZLDH
16
50
1
m³/h, relating to 1 bara and 20°C at the compressor suction capacity. Subsequently compressed to 7 bare and 35°C inlet
temperature to the dryer at 100% relative humidity – for pressure dewpoints of -25°C and -40°C.
2
In accordance with DIN ISO 228 (BSP-P); alternatively ANSI B 1.20.1 (NPT-F).
Noise emission
Noise level : +3 dB (A)
65 86 dB(A)
1
relative to free field measurement, 1 m surr. field
Drying agent
Chamber 1
100 % molecular sieve
Chamber 2
100 % molecular sieve
Dimensions
Please heed to the dimensional drawings and the according table containing dimensions and weight on page 61.