Maintenance and repair of the dryer
K-MT1-8_EN_082014 43
Replace the element in the fine filter muffler
Depressurise the dryer and shut it down (see page 37).
Undo knurled screw on the lid cap
and remove cap.
Unscrew old filter element. Arrows
on the element bottom mark the
direction of rotation.
Insert new filter element and screw
on tightly.
Renew muffler element
means of the knurled screw.
Restart dryer (see page 38).
Renew dewpoint sensor
To ensure precision dew point
measurement, it is recommended
to replace the dew point sensor
every year. This period depends
however on the actual application
and might thus be extended
accordingly.
Dewpoint sensor (1)
The dew point sensor is a sensitive measuring device. It can be damaged
if subjected to forceful vibrations or shocks. Therefore, please handle the
dew point sensor with great care at all times.
In order to limit the impact on the dryer operation to a minimum, we recommend
that you contact the manufacturer well in advance and order a new dewpoint
sensor.
After receipt of the new pressure dewpoint sensor, replace the sensor as follows:
Hold the box of the dewpoint sensor ready.
Release pressure from dryer and shut down the unit (see page 37).