Maintenance and repair of the dryer
K-MT1-8_EN_082014 49
Fill with new drying agent and remount check valve plate
Risk of falls!
The dryer must not be misused as a climbing aid. The components have
not been designed for such loads and could fracture.
Only use approved climbing aids when filling the chambers.
Slowly fill up with new drying agent in the chamber. If necessary, use a
funnel. Take special note of the next step.
Ensure that the drying agent is filled into the chambers with a high bulk
density.
Note:
To achieve an optimum bulk density, we recommend using a
"snowstorm" filling pipe available from the manufacturer.
Subsequently, position the perforated plate onto the check valve plate, align
them properly and secure them.
Reaffix the check valve plate:
Use a dyamometric key to tighten the
screws, and take care to observe the
following torques:
25 Nm in the case of K-MT 1-4
50 Nm in the case of K-MT 6-8
Tighten the screws crosswise in
accordance with the sequence shown
on the right.
Repeat the process once.
Correctly affixing the check valve plate
Restart the dryer (see page 38). Check that the connection is leak tight.
Operate the dryer for two cycles, then shut it down again.
Replace sound absorber as described on page