Identify and eliminate faults
K-MT1-8_EN_08—2014 51
Service technician
Solenoid valve Y3/Y4 cannot be
opened.
Check supply voltage, cable, contacts
and solenoid; replace, if necessary.
Solenoid valve Y3/Y4 cannot be opened
properly
(audible humming sound or valve
flapping).
Check spring and solenoid; replace, if
necessary. Check solenoid valve for
contamination; clean or replace, if
bled
Solenoid valve Y3/Y4 cannot be closed
properly (audible humming sound or
valve flapping).
Check spring and solenoid; replace, if
necessary. Check diaphragm; replace,
Dryer is excessively
bled
Solenoid valve Y1/Y2 cannot be closed.
Check solenoid and diaphragm;
replace, if necessary.
With dewpoint-sensing control (optional)
Service technician
limit exceeded
Drying capacity
exceeded.
See instructions for commissioning.
If the drying agent is wet, replace it.
defective
irreversibly
or
–999
cable or sensor defective
or sensor adapter
defective.
Visual inspection; check power
supply (24 V to terminals 4 and 6).
Replace defective component(s).
interval. Regular
maintenance tasks must
be carried out.
after every 8000
operating hours.
Inform the manufacturer’s service
staff and order the appropriate
service kit. The package includes a
dongle with which you can reset the
operating hours counter after
maintenance has been carried out.
For instructions on how to use the
dongle see the enclosed information
sheet (in the service kit).