EasyManua.ls Logo

Parker LVD1 - Signal Cable Connections; Signal Cable Connection Diagram; Frequency Input Connection

Parker LVD1
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin S.p.A. - Divisione S.B.C. LVD User’s Manual
21
2.7 Signal cable connections
A twisted and screened pair must be employed for the analogue reference.
The cable for simulated encoder signals must comprise three twisted pairs with a common
screen.
Screened cables are recommended also for digital inputs and outputs.
Minimum size of all signal wires is 0.35 mm
2
2.8 Signal cable connection diagram
CONTROL
LVD
REF+
REF-
A
/A
B
/B
C
/C
8
7
X7 - Reference in
15
1
2
3
4
5
6
7
X4 - Encoder out
24Vdc
x
1
5
X7 - Inputs
1
X6 - Outputs
TO EARTH BUSBAR
4
AXIS
Encoder in
Enable
Input
Reference
Output with
contact
12
voltage free contact output
( drive ok )
2.9 Frequency input connection
The RS422 type frequency input can be software-configured in two modes: the first
(default) to accept quadrature signals from encoders, the second is frequency/direction mode
(refer to the chapter Fundamental parameters bit b42.5).
In the former case follow this connection diagram:

Table of Contents