Parker Hannifin S.p.A. - Divisione S.B.C. LVD User’s Manual
26
The units of measurement and main resolutions of the parameters are as follows:
3.1 Using the optional keypad
The keypad-display module is designed to provide an intuitive operator interface. It can be
used to program operating data, monitor system status and enter commands. The module has
only three keys, located at the top of the front panel just below the display. The keys are
marked: [M], [+] and [-].
[M] is used to change the display mode and consequently also the function of [+] and [-].
There are two display modes: parameter mode and parameter value mode. When the unit is
powered up the message "IdLE" (drive disabled) or "run" (drive enabled) is displayed
provided there are no active alarms; this is also the position of parameter Pr0.
Press [+] or [-] to scroll through the parameters.
If you want to check a parameter value, press [M]; when the value is shown it can be
updated using [+] and [-]. To return to parameter mode press [M] again.
Data can be displayed in various forms, depending on the parameter in question.
If you need to increase (or decrease) a parameter value quickly, press [M] while the up key
[+] (or down key [-] ) is pressed.
M
Pr. 01
Pb. 40
+
-
+
-
Pr. 02
+
-
In. 00
In. XX
+
-
M
XXXXX
M
M
XXXXX
+
-
+ 1
+ 9
M
- 1
- 9
M
M
M
XXXXX
+
-
+ 1
+ 9
M
- 1
- 9
M
M
M
b40.XX
+
-
1
0
M
M
XX
+
done
M
PLC inst.
M
+
-
1st oper.
M
+
-
2nd oper.
M
+
-
3rd oper.
M
+
-
LVD keypad
Pb. 99
M
XX
+
-
b99.XX
M
+
-
IDLE
Parameter Type Unit Resolution
speed Rpm 1
acceleration seconds / 1000 rpm. 0.001
position 4096 steps / revolution 1/4096 of a revolution
current Drive peak current percentage 0.1