No combustible object must be placed within 1.5 metres of the battery.
The charger is maintenance-free.
Disconnect the charger before cleaning it. Clean the charger case using a damp cloth and a gentle
detergent.
If the battery is not used for 10 days, it discharges automatically to prepare for storage. During this phase
it will become warm.
INCIDENTS
If your tool no longer works:
1– Turn off the battery (check that the LED is off).
2– Check the battery is charged, as shown on the gauge.
3– Check the lead is connected and the thumb-wheel tightened.
4– Turn on the battery (LED is on).
5– Press the trigger and the safety lock (depending on the tool).
6– If the tool does not work, return the complete equipment in its original packaging to a certied repair
service.
NEVER ATTEMPT TO OPEN ONE OR MORE ELEMENTS OF THE "BATTERY" OR THE CHARGER
UNIT (you risk damaging them and most importantly, you void the warranty).
SUMMARY OF CHARGE INDICATOR AND BEEP MESSAGES
NORMAL MESSAGES
USAGE
xed Battery charge level (0 to 99)
with 1 beep per minute Battery empty, recharge immediately
ashing with 1 beep every 10
seconds
Stop using, recharge immediately
CHARGING
ashing every 4 seconds Battery charge level (0 to 99)
xed Charging complete
STORAGE
ashing Standby mode after 10 days of non-use (50 to 99)
DEGRADED MODE MESSAGES
USAGE
and alternately Stop the tool; the battery temperature is too high
Long beep and 1 short beep Stop the tool: intensity is too high
Long beep and 4 short beeps Stop the tool; the tool temperature is too high
CHARGING
and alternately Charge interrupted: Battery temperature too low
and alternately Charge interrupted: Battery temperature too high
FAULT MESSAGES
USAGE
and beeps every 2 minutes for
24 hours
Voltage too low after 3 hours of non-use. Recharge battery
immediately
CHARGING
and alternating and continuous
beep
Battery problem
and alternately Charger problem

Other manuals for pellenc Prunion