Color Sync Controller Installation Guide
Color Sync Controller Installation Guide
12
13
L
N
12 VAC
Step Down
Transformer
12 VAC Pentair
Color LED Lights
Red (Hot Load line -
Transformer / Light)
Black (Hot Line Incoming Power)
White/Blue (Neutral)
LOAD
NEUTRAL (WHT)
LINE (BLK)
Outlet box screw hole (X6)
BLACK
RED
WHITE
Hot Load Line (Transformer/Light)
Neutral (White) Line (to Light or
Hot (Black) Line (incoming power)
transformer and incoming neutral)
LOAD
NEUTRAL (WHT)
LINE (BLK)
Hot Load Line (Transformer/Light)
Neutral (White) Line (to Light or
Hot (Black) Line (incoming power)
transformer and incoming neutral)
LOAD
NEUTRAL (WHT)
LINE (BLK)
WIRING LIGHTS TO THE COLOR SYNC™ CONTROLLER
Color Sync Controller
(RearView)