IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INTELLIVALVE
2-WAY, 3-WAY VALVE ACTUATOR
INSTALLATION AND
USER’S GUIDE
AUTO
OFF
SERVICE
MODE
0
24
2
4
6
8
10
12
14
16
18
20
22
LR
SET
CCW/CW
SAVE
X
CW
X
CCW
Question and Answer IconNeed help?

Do you have a question about the Pentair INTELLIVALVE and is the answer not in the manual?

Pentair INTELLIVALVE Specifications

General IconGeneral
Voltage24V AC
Valve TypeDiverter Valve
CommunicationWired
Operating Temperature32°F to 122°F (0°C to 50°C)
FeaturesProgrammable
TypeAutomatic Valve Actuator
CompatibilityIntelliCenter, EasyTouch, ScreenLogic

Summary

Important Warning and Safety Instructions

IntelliValve Actuator Overview

Installation

Installing the IntelliValve Valve Actuator

Describes how to install the IntelliValve Valve Actuator on 2-way, 3-way, or 3-way Y valve assemblies.

Mounting the IntelliValve Actuator onto the Valve

Aligns the actuator shaft over the valve shaft and secures it with mounting screws.

Operation

Mode Button Functions

Explains the functions of the MODE button and its different operational modes.

Setting Home Position

Details the default diverter end points and the 'Home' position setting.

SET Mode Configuration

Step-by-step guide to set diverter travel end points using arrow buttons.

Service Mode Operation

Manual control mode for pool maintenance or service purposes.

Changing Home Position

Explains how to reverse the diverter's Home position between end points.

Example: Split Pool/Spa Flow

Demonstrates setting end points for partial water flow to spa/spillway.

Valve Diverter Positions

3-Way Valve Position Examples

Illustrates IntelliValve LED positions relative to 3-way valve diverter seal positions.

2-Way Valve Position Examples

Illustrates IntelliValve LED positions relative to 2-way valve diverter seal.

3-Way Y Valve Position Examples

Illustrates IntelliValve LED positions relative to 3-Way Y valve diverter seal.

Connecting Power to IntelliValve Actuator

EasyTouch Control System Connection

Details connecting the IntelliValve to the EasyTouch control system circuit board.

IntelliTouch Control System Connection

Details connecting the IntelliValve to the IntelliTouch control system circuit board.

Troubleshooting

Actuator Did Not Move or Reversed

Addresses issues where the actuator fails to move or reverts to a previous position.

Stuck Actuator Troubleshooting

Troubleshoots a stuck actuator with blinking LEDs and an illuminated Service LED.

Valve Not Rotating When Commanded

Checks if the IntelliValve actuator is in AUTO mode when the valve is not rotating.