12 - MASTER PROGRAMMING MODE
SXT continued
15. Flow Meter Type (Display Code FM)
Press the Extra Cycle button. Use this display to set the type
of ow meter connected to the control. This option setting is
identied by "FM" in the upper left-hand corner of the screen.
Use the Up and Down buttons to select one of the 8 available
settings.
Abbreviation Description
P0.7 3/4" Paddle Wheel Meter
t0.7 3/4" Turbine Meter
P1.0 1" Paddle Wheel Meter
t1.0 1" Turbine Meter
P1.5 1.5" Paddle Wheel Meter
t1.5 1.5" Turbine Meter
P2.0 2" Paddle Wheel Meter
Gen Generic or Other non-Fleck Meter
Figure 27
16. Meter Pulse Setting (Display Code K)
Press the Extra Cycle button. Use this display to specify the
meter pulse setting for a non-standard ow meter. This option
setting is identied by "K" in the upper left-hand corner of
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
Figure 28
17. End of Master Programming Mode
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
Fleck 5800 LXT & SXT Downow/Upow MR12 • 15