FLECK 7000XTR Service Manual 19
GENERAL SERVICE HINTS FOR METER
CONTROL
Problem Cause Correction
Softener delivers hard water Reserve capacity has been exceeded. Check salt dosage requirements and reset reserve
capacity to provide additional reserve.
Meter is not measuring flow. On Mechanical Meter: Check with meter checker kit.
If volume is not registering, check the meter cap and
impeller for debris, and ensure they can move freely.
On Electronic Meter: Check for a short in the meter
cable. Ensure that it is programmed as a meter, and
that the turbine and impeller can move freely.