OPERATING THE PUMP 2/25
PUMP OPERATING MODES
The IntelliFlo
®
VSF Pump can be programmed in three different modes:
Programs 1-4 can be programmed in all three modes.
Programs 5-8 can only be programmed in Schedule mode since there are no buttons on
the control panel for Programs 5-8. The default setting for Programs 5-8 is “Disabled”.
Manual
Assigns a speed or flow to one of the four Program buttons on the control panel. This mode
can only be used for programs 1-4. Programs 1 and 2 are Manual by default.
To operate in Manual mode, press one of the four program buttons and then press the Start/
Stop button. The pump will run the assigned speed or flow assigned to that program button.
Egg Timer
Programs 1-4 can be programmed to run at a certain speed or flow and for a duration of time
once a program button is pressed.
Programs 3 and 4 are Egg Timers by default. If you desire a different method of operation,
programs 3 and 4 can be changed to Manual mode in the control menu.
To operate in Egg Timer mode, press a program button and then press Start/Stop. The
pump will run that setting for the set amount of time and then turn off.
Schedule
Programs 1-8 start and stop at a specific time during a 24 hour period. Speeds or flows
programmed in Schedule mode will override any manually selected speed or flow once the
next Schedule command commences.
Program Types
This pump can run saved programs at either constant speeds or constant flow rates. This
gives the user the ability to precisely assign the output from the pump so that no energy is
wasted and the job is completed accurately.
13
Program Menu Tree Options
Set Flow
Manual
Schedule
Egg Timer
Set Speed
Set Type
Set Flow
Set Type
Set Start Time
Set Stop Time
Set Flow
Set Speed
Set Flow
Set Duration
Set Type
Set Flow
Set Speed
Set Flow
Program 1-4
Schedule
Disabled
Default: Disabled
Set Type
Set Start Time
Set Stop Time
Set Flow
Set Speed
Set Flow
Program 5-8