Chapter 4 35943
Page 14
Schedules
The schedules which follow must be applied at the interval (hours or months) which occur rst.
A First service at 25/50 hours D Every 1000 hours
B Every day or every 8 hours E Every 2000 hours
C Every 500 hours or 12 months F Every 3000 hours
A B C D E F Operation
●
Check the amount of coolant in the header tank
●
Check the engine for leakage of oil and coolant
●
Check the specic gravity of the coolant (2) (3)
● ●
Check the tension and the condition of the drive belt
●
Check the impeller of the raw water pump
●
Check the strainer at the raw water pump outlet
●
Check the sea water strainer
● ●
Drain water from the fuel pre-lter (1)
●
Renew the element / canister of the fuel lter
●
Check the atomisers, always renew the clamps (2)
●
Check the amount of lubricating oil in the sump
●
Check the lubricating oil pressure at the gauge
●
Renew the engine lubricating oil (4)
●
Renew the canister of the lubricating oil lter
●
Remove and clean the pipe(s) for the engine breather
●
Renew the engine breather (2)
●
Clean or renew the element of the air lter
●
Check all hoses and connections
● ●
Check the valve tip clearances of the engine, and adjust if necessary (2)
●
Check the audible warning system which protects the engine
●
Check the alternator, the starter motor etc.(2)
●
Check the glow plugs (2)
(1)If one is tted.
(2)By a person who has had the correct training.
(3)Renew the coolant every 6 years. If a coolant inhibitor is used instead of coolant, it should be renewed every 6 months.
(4)The oil change interval will change with the amount of sulphur in the fuel (see the table and the Fuel Specication in section 5). The
interval to change the canister of the lubricating oil lter is not affected.
Note: To ensure that the engine runs at maximum efciency, the operations that follow must be done every
12 months or less. If the raw water is excessively contaminated, these operations should be done more
frequently.
• Clean the tube stack of the heat exchanger for the closed circuit coolant