EasyManua.ls Logo

Perkins 4016-E61TRS - Service Schedule

Perkins 4016-E61TRS
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
22 Users Handbook, TSL 4230, Issue 4
4016-E61TRS
Service schedule
Oil and filter change intervals
For engines running on gas to the specification given in "Gas specification" on page 41 and using the approved
lubricating oil given in "Lubricating oil recommendations" on page 42, the oil and filters must be changed after
the first 500 hours of operation.
Subsequent oil and filter changes must be determined using an oil analysis programme. For further details
refer to "Oil and filter change programme" on page 42.
The procedures indicated in the service schedule require reference to the following publications:
l Users Handbook - TSL 4230 (UH)
l Workshop Manual - TSL 4235 (WM)
l Diagnostic Manual - TSL 4233 (DM)
A service - First 500 hour
B service - 2,000, 6,000, 18,000 and 22,000 hours
C service - 4,000 and 20,000 hours
Description Manual
Check EMS logged events and record
DM
Check EMS logged diagnostic codes, record and rectify
Oil and filter change UH
Clean the filter gauze for the piston cooling jet oil gallery UH
Equalise bridge pieces and set valve clearances UH
Check and clean spark plugs, reset gap UH
Description Manual
Check EMS logged events and record
DM
Check EMS logged diagnostic codes, record and rectify
Equalise bridge pieces and set valve clearances UH
Check valve and seat recession UH
Check and clean spark plugs, reset gap UH
Closed circuit breather element - renew UH
Air filter - renew (subject to environmental conditions) UH
Check emissions, adjust if necessary DM
Description Manual
Check EMS logged events and record
DM
Check EMS logged diagnostic codes, record and rectify
Clean the filter gauze for the piston cooling jet oil gallery UH
Equalise bridge pieces and set valve clearances UH
Check valve and seat recession UH
Check and clean spark plugs, reset gap UH
Breather element - renew UH
Air filter - renew (subject to environmental conditions) UH
Calibrate oxygen sensor UH - DM
Check emissions, adjust if necessary DM
This document has been printed from SPI². Not for Resale

Table of Contents