12 - 26
1 101 Control panel key tone A, B, C 0 – 1 1
(0 = off, 1 = on)
6 605 Speed display B, C 0 – 1 0
(1 = yes, 0 = no)
607 Max. speed B,C 300 – 3500 3000
609 Cutting speed 1 B, C 60 – 300 180
7 700 Needle position 0 A, B, C 0 – 255
(needle reference position)
702 Needle position 1 (needle lowered) A, B, C 0 – 255 25
703 Needle position 2 (take-up lever raised) A, B, C 0 – 255 215
705 Needle position 5 (end of cutting signal 1) A, B, C 0 255 180
706 Needle position 6 (start cutting signal 2) A, B, C 0 – 255 25
707 Needle position 9 A, B, C 0 – 255 164
(start thread tension release)
760 Fixed value multiplier (200) for stitch
counting A,B, C 0-250 5
797 Hardware test C 0 – 1 0
(0 = no, 1 = yes)
798 User level 0, 1, 11 0
0 = operator level
1 = mechanic level
11 = service level
799 Selected machine class C 1 1
8 800 Direction of motor rotation C 0 – 1 1
12.08.03 List of parameters
Group
Parameter
Setting
range
Set
value
User
lever
Description
Further parameters are listed in the Motor Instruction Manual.