Adjustment
11 - 38
Fig. 11 - 36
Align clamp spring 5 (screws 6) in the elongated hole in accordance with requirement 2
and 3 - if necessary carrier 1 (screws 2) as well.
In this position, and taking care to ensure that carrier 1 is parallel to the machine
bedplate, tighten screws 2 and 6.
3
5
12
7
5
8
7