9 - 1
Setting up
9 Setting up
All instructions and regulations in this instruction manual must be observed.
Special attention must be given to all safety regulations!
All setting-up work must only be done by personnel with the necessary
training. For all setting-up work the machine must be isolated from its power
supply by turning off the on/off switch or removing the machine plug from the
electric power socket!
9.01 Inserting the needle
Switch off the machine!
Danger of injury if the machine
is started accidentally!
Only use needles from the
system intended for the
machine, see Chapter 3
Specifications.
Bring the needle bar into its highest
position.
Loosen screw 1.
Insert the needle 2 as far as possible.
The long needle groove must be facing
forwards.
Tighten screw 1.
Fig. 9 - 01
1
2