19 | P a g e
CAUTION: Clearing faults through the CLEAR MEMORY menu will clear ALL faults in
the Restart Log and all fault counters will be reset to zero. If any number of automatic
restarts have been allowed through parameters in the Auto Restart Parameters (Table 15),
the counter on these faults will be set to zero.
Programming Tip
When the drive has faulted and is programmed to automatically restart after a time delay,
the display will count down the remaining time to start. Press both up arrow and down
arrow for one second to interrupt the countdown and start the motor.
If the drive has faulted and no auto restart is allowed, the display will indicate the type of
fault that has occurred on the top line and the second line will read RESTART? ENTER.
Press ENTER to clear the fault and restart the load.
The number and type of faults are also recorded in the Fault Log. In this Log each fault is
recorded with a time and date stamp (up to the most recent 20 faults). The Fault Log is
permanent and cannot be cleared. See Section 8.1 for more information on the Fault Log.