www.phocos.com 14 | P a g e
3. Remove the cable connected to t he display module(Fig. 11 → ③).
4. Screw the bracket removed in Fig. 11 → ①back in place (Fig. 11 → ④).
Fig. 11: Remote display removal
5. Drill the three mount ing holes in the marked distances of 70 mm, 2.76 in into each other (Fig. 12, left). Use
M3, size no. 4 diameter screws.The screw heads mustbe between 5 ~ 7 mm, 0.2 ~ 0.3 in. Screw the bottom
two screws into the wall where the display moduleis to be mounted and let the screw headsprotrude 2
mm, 0.08 in. from the wall. Slide the display down on the protruding screw heads. Now insert and tighten
the third screw at the top (Fig. 12, rig ht).
Fig. 12: Remote display mounting hole locations
6. Install one end of the Ethernet patch cable (not included) into socket (Fig. 2, top right) on the display
module ( right side). Installthe other end of the Ethernet patch cable into socket (Fig. 2, bottom left) on
the Any-Grid unit.
7. If using Lithium batteries designed for battery managementsystem (BMS) communication such as
Pylontech batteries, please visit www.phocos.com for a current list of batteries supported with BMS
communication. Connect t he special battery BM S cable (ask your dealer for details) to socket (Fig. 2).
CAUTION: Ensure the battery and BMS is compatible with the Any-Grid and that the pin location is
correct before connection. Damage to any communication port or the battery due to incorrect
connection or cables is not covered by warranty. Do not use any inverter communication cables
included with your battery, consult your Phocos dealer for appropriate Any-Grid cables instead.
Pin (see Fig. 2) 1 2 3 4 5 6 7 8
Function
RS-232 RX RS-232 TX RS-485 B +12 Vdc RS-485 A CAN H CAN L GN D