Error codes
8663_en_03 PHOENIX CONTACT 21
0B01 A hardware or firmware error occurred. Restart the device. If the
problem still occurs, please
contact Phoenix Contact.
0B02 A hardware or firmware error occurred.
0B03 A hardware or firmware error occurred.
0B04 A hardware or firmware error occurred.
0B05 Invalid parameters Check the parameters.
0B06 Access not supported. (E.g., write protection) Restart the device. If the
problem still occurs, please
contact Phoenix Contact.
0B07 Object does not exist.
0B0C A hardware or firmware error occurred.
OBC1 Supply voltage not available for the local bus. Too many
devices connected or the higher-level power supply unit
is too weak.
Use a suitable power supply
unit.
Check the power consump-
tion of the devices; if re-
quired, use a power module
for communications power or
install a further Axioline F sta-
tion.
0BDE Synchronization failed. Trigger signal does not corre-
spond to the specification.
Check the synchronization
signal of the higher-level sys-
tem. Make sure that the cycle
time specification is properly
selected.
Table 2-1 Error codes for user errors [...]
Code
(hex)
Additional code Meaning Remedy

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phoenix Contact Axioline F AXC Series and is the answer not in the manual?

Phoenix Contact Axioline F AXC Series Specifications

General IconGeneral
BrandPhoenix Contact
ModelAxioline F AXC Series
CategoryControl Unit
LanguageEnglish

Related product manuals