- Connect a tester «10» (set as ohmmeter) to the
thermistor «2» as shown in the figure.
- Immerse the thermistor in a container «11» with
coolant.
In the same container, immerse a thermometer
«12» with a temperature range of 0°÷150° (32°
÷302°F).
- Place the container on a stove «13» and warm
up the coolant slowly.
- Check the temperature indicated on the ther-
mometer and the thermistor value indicated on the
tester.
- Make sure the thermistor varies according to
temperature as indicated.
COOLANT TEMPERATURE °C (°F) / RESISTANCE VALUES (OHM)
Specification
Desc./Quantity
115° (239°) Approx. 26 ÷ 10
50° (122°) Approx. 205 ÷ 50
CAUTION
IF THE VALUES DO NOT VARY OR DIFFER TOO MUCH FROM THOSE INDICATED IN THE TABLE,
REPLACE THE THERMISTOR.
Montaggio
- Carry out removal operations in reverse order.
- Fill and bleed the cooling system.
Carnaby 125 - 200 Electrical system
ELE SYS - 93