Installation of several adjacent safety light grids
Fig.: Using several adjacent safety light curtains
Legend
Rx Receiver of a safety light curtain
Tx Transmitter of a safety light curtain
[1] Connecting the safety light curtain with an opaque surface to shield the safety light
curtain on the right
[2] Connection of the safety light curtain aligned with [1]
[3] Connection of safety light curtain without shielding, but in the orientation opposite
to [2]
[4] Connection of the safety light curtain with beam code A-coded
[5] Connection of the safety light curtain with beam code B-coded
} Beam coding of two safety light curtains
If two safety light codes are to be used in parallel, a beam coding of the safety light
curtains is recommended. When connecting the safety light curtain to the supply
voltage, the safety light curtains are connected to different pins. This guarantees a dif-
ferentiation of the beams, and transmitter and receiver can not interfere with each
other.
If several adjacent safety light curtains need to be installed, steps must be taken to ensure
that the transmitter on one safety light curtain does not interfere with the receiver on an-
other safety light curtain.