PSEN opII3H Series
Operating Manual PSEN opII3H Series
1003503-EN-05
| 38
} Response and stopping times must fulfil the requirements in Maintaining the safety dis-
tance
Ensure that the safety light curtain’s response time and the machine's stopping time fulfil
the requirements in Maintaining the safety distance.
} Check beam coding
Is beam coding displayed correctly at the receiver (see Checking of safety light curtains
with beam coding [ 43])?
} No intense or flashing light sources in the vicinity
There may be no especially intense or flashing light sources in the vicinity of the safety
light grid.
} Ambient conditions
Please observe the environmental conditions [ 16].
} Use of deviating mirrors
Check all areas that are bounded by a deviating mirror.
Operation
Display elements
The safety light curtain’s operating status is indicated with LEDs in the end caps of the con-
nection side of the receiver and on the transmitter.
Device status
} Reception quality:
III: Best quality
I: Worst quality
} Status of the beam coding when the
protected field is interrupted
OSSD status (protected field LED)
LED indicator on the receiver

Table of Contents