PSEN opII3H Series
Operating Manual PSEN opII3H Series
1003503-EN-05
| 57
Mechanical data 632029 632030 632031
Max. torque setting
Clamping screw 1,1 Nm 1,1 Nm 1,1 Nm
Installation screw 3 Nm 3 Nm 3 Nm
Fixing screw 0,7 Nm 0,7 Nm 0,7 Nm
Dimensions
Height 1.504 mm 1.654 mm 1.804 mm
Width 35 mm 35 mm 35 mm
Depth 40 mm 40 mm 40 mm
Weight 4.250 g 4.655 g 5.060 g
Where standards are undated, the 2015-12 latest editions shall apply.
Classification according to ZVEI, CB24I
The following tables describe the classes and specific values of the product interface and
the classes of interfaces compatible with it. The classification is described in the ZVEI posi-
tion paper "Classification of Binary 24 V Interfaces - Functional Safety aspects covered by
dynamic testing".
Safe 1-pole HL outputs
Source Drain
Safety switch C2 Evaluation device C1, C2
Source parameters Min. Typ. Max.
Test impulse duration - - 300 µs
Rated current - - 0,1 A
Capacitive load - - 40 nF
Safety characteristic data
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
Operating
mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN62061
SIL CL
EN62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
Sensor, 2-
channel PL d Cat. 3 SIL CL 2 2,00E-07 – 2,00E-03 20
Explanatory notes for the safety-related characteristic data: