Installation and alignment
Please note:
} The optical surfaces of the transmitter and receiver must be parallel to each other and ori-
ented opposite to each other.
} The connection sides of the transmitter and receiver must be on the same side and at the
same height (see diagram).
[1] [2] [1] [2]
[3]
[3]
[3]
[3]
Legend
[1] Transmitter
[2] Receiver
[3] Connection cable
} The distance between the transmitter and receiver must be within the operating range of
the safety light curtain used (see Technical details [ 48]).
} The installation surface must be at least as wide as the standard installation kit
} The installation surface may have a flatness imperfection of no more than 1.5mm.