Fig.: Example for using deviating mirrors
Legend
[1] Transmitter
[2] Receiver
[3] Hazardous area
[4] Deviating mirror
[5] Minimum safety distance
[6] Distance between the deviating mirrors
[7] Distance from transmitter to deviating mirror
[8] Distance from deviating mirror to receiver
Dead zones
Use of the standard installation kit results in a dead zone of 15.4mm on both sides of the
safety light curtain.
If you want to use the safety light grid without dead zones, use the
PSENopIIAdvBracketKit for safety light curtain installation (see Dead-zone-free
installation [ 6]).
Use the installation information provided in the PSENopIIAdvBracketKit operating
manual.