Recovery flowchart (1-3)...Changing the VOL OFFSET setting
[From the Main flowchart (1) / Recovery flowchart (1-2)]
RST MASK 19 (Green 626)
Display RST MASK 09 (Pink). / [MKR S09]
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Set VOL OFFSET to the current setting value minus 123. / [VOF ∗∗∗]
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 157 or greater.
Current VOL OFFSET < 163?
[To the Main flowchart (1)]
Set VOL OFFSET to the current setting value plus 45. / [VOF ∗∗∗]
Determine the current VOL OFFSET setting value as the final value.
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
Recovery flowchart (1-2)...Changing the VOL OFFSET setting
[From the Main flowchart (1) ]
RST MASK 18 (Red 626)
Display RST MASK 19 (Green 626). / [MKR S19]
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 157 or greater.
Current VOL OFFSET < 163?
[To the Recovery flowchart (1-3)]