[17] QPB (Panel Main Operation Information)
Command
Format
Effective status Function Remarks
[QPB] Every time
To acquire data on current statuses
managed by the Panel Main
microcomputer
Data on operation of the display main unit can be acquired.
Return data: 3 (ECO) + 53 (DATA) + 2 (CS) = 58 Byte
ECO Echo back 3 "QPB"
1 Data on panel temperature 5 ∗∗∗∗∗ Temperature of the panel (in Centigrade) (Tmd)
2 Delimiter 1 "," Comma
3 Unit temperature data 1 5 ∗∗∗∗∗ Temperature inside the unit (in Centigrade) (T1)
4 Delimiter 1 "," Comma
5 Unit temperature data 2 (reserved) 5 ∗∗∗∗∗ Temperature inside the unit (in Centigrade) (T2)
(Reserved, All digits are padded with asterisks.)
6 Delimiter 1 "," Comma
7 Unit temperature data 3 (reserved) 5 ∗∗∗∗∗ Temperature inside the unit (in Centigrade) (T3)
(Reserved, All digits are padded with asterisks.)
8 Delimiter 1 "," Comma
9 Fan rotation speed A 1 A Fan setting A (S: stop, L: Low, H: High, and A: Auto)
10 Fan control A/D value (A) 3 ∗∗∗ Fan control D/A value, A, decimal code
11 Fan rotation speed B 1 A Fan setting B (S: stop, L: Low, H: High, and A: Auto)
12 Fan control A/D value (B) 3 ∗∗∗ Fan control D/A value, B, decimal code
13 Room Light Sensor level 1 5 0-7, padded with an asterisk during the sensor is off
14 Room Light Sensor A/D value 4 ∗∗∗∗ Brightness sensor A/D value, decimal code
15 Dummy 1 2 ∗∗ All digits are padded with asterisks.
16 System Operation mode of the panel 1 S
S: System Operation mode, T: Standalone Operation mode
17 Dummy 2 2 ∗∗ All digits are padded with asterisks.
18 Audio muting 1 0 0: Canceling muting, 1: Muting
19 Reserved 10 ∗∗ All digits are padded with asterisks.
CS Check sum 2 (CS)
Data Arrangement
Data
Length
Output
Example
Remarks