EasyManua.ls Logo

Pioneer PDP-435PG - DIAGNOSIS WITH THE AID OF FACTORY MODE; POWER-DOWN LOG (INFORMATION-PANEL PD); SHUTDOWN LOG (INFORMATION-PANEL SD)

Pioneer PDP-435PG
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDP-435PE
61
5678
56
7
8
C
D
F
A
B
E
S5201
A
(
(
A
IC5214
IC5215
OR
OR
IC5401
IC4
DC-DC
CONVERTER
OR
AD1
AD1
D5 - D8
D9 -D12
X1
Y1
D14
D13
D1
SCAN_PD
YDRIVE_PD
YDD_CNV_PD
YSUS_PD
SCAN_5V_PD
XDRIVE_PD
XDD_CNV_PD
XSUS_PD
ADR_PD
PD_MUTE
PS_PD
PD
DCC_PD
PD_TRIGGER
P2
8
0
9
-
3
4
5
6
7
=
~
2
ADDRESS ASSY
(upper)
DIGITAL VIDEO ASSY
ADDRESS ASSY
(lower)
X DRIVE ASSY
Y DRIVE ASSY
POWER SUPPLY UNIT
IC5208
PD-MUTE
circuit
• Block diagram of the power-down signal system
Note:
The figures 1 - = indicate the number of times the
LED flashes on the panel when power-down occurs in
the corresponding route.
Relay control
Protection
circuit
IC5201
module
microcomputer
Flashes in a case of power-down
other than power-supply-related
power-down (Red LED:D5201)
Flashes in a case of
power-supply-related
power-down
(Orange LED: D158)