ENGLISH
13
The Temperature Control Dial allows you to
set your desired smoking temperature. Rotate
the knob to select from Smoke, any of the eight
temperature presets, or High.
The Off Setting on the Temperature Control Dial is
the off mode for the unit. The unit will not function
on this setting.
The Smoke Setting on the Temperature Control
Dial is the start-up mode for the unit. The grill
operates at the lowest temperature, without the
fire going out.
The High Setting on the Temperature Control
Dial is the highest heat level for the unit. The
grill operates at the highest temperature. When
the lid is open, the grill will run at this speed to
compensate for the loss of heat in the barrel.
The LED Screen is used as the information center for
your unit. The LED screen will display your desired
cook temperature (), actual cook temperature
(ACTUAL), and the "P" setting selected ("" ).
See
Troubleshooting
for more information on
error codes.
888 Displays once connected to AC
power.
Flashing Grill temperature is below 66˚C
/ 150˚F.
Flashing • • • Indicates the igniter is on.
"" Indicates the current "P" setting
selected.
Indicates the desired cooking
temperature.
ErH The grill has overheated.
ErR Temperature probe wire not
connecting.
ErP Power interruption while in
operation.
The "P" SET Button is used to select one of the
eight temperature fine tunings. Use this feature
to change the "P" setting to accommodate to
your cooking style and cooking environment, as
preferred. With a short push of the recessed button,
the setting increases from P0 to P7, then repeats.
Adjustments are best made when the Temperature
Control Dial is set to Smoke, which allows for
manual control of the pellet feed system. Default
setting is "P4".
“P” SET
SET
“P” SET ACTUAL ˚F
SET
Smoke
O
High
300
350
250
225 400
450
475
Smoke
“P” SET
O
High
200
“P” SET ACTUAL ˚F
SET
300
350
250
225 400
450
475
Smoke
O
High
200
“P” SET
“P” SET ACTUAL ˚F
SET
“P” SET