15/124
15 /20
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
translated from italian
K600
4
LONG RESET KEY KEYING
We now go on to Direct change of the calibration factor: the word “Direct”
appears together with the Currently Used calibration factor. In the boom
le part of the display, an arrow appears (upwards or downwards) defining
the direction (increase or decrease) of change of the displayed value when
subsequent operations 5 or 6 are performed.
5
RESET
SHORT RESET KEY KEYING
Changes the direction of the arrow. The operation can be repeated to alternate
the direction of the arrow.
6
CALCAL
CAL
CAL
SHORT/LONG CAL KEY KEYING
The indicated value changes in the direction indicated by the arrow
- one unit for every short CAL key keying
- continually if the CAL key is kept pressed. The speed increase rises by keeping
the key pressed. If the desired value is exceeded, repeat the operations from
point (5).
7
LONG RESET KEY KEYING
The Meter is informed that the calibration procedure is finished.
Before performing this operation, make sure the INDICATED value is that
required.
8 NO OPERATION
At the end of the calculation, the new USER K FACTOR is shown for a few seconds,
aer which the restart cycle is repeated to finally achieve standby condition.
IMPORTANT: From now on, the indicated factor will become the calibration
factor used by the Meter and will continue to remain such even aer a baery
change
9 NO OPERATION
The Meter stores the new work calibration factor and is ready to begin dispensing,
using the USER K FACTOR that has just been changed.
8 METER CONFIGURATION
The METER feature a menu with which the user can select the main measurement unit, Quarts (Qts), Pints
(Pts), Litres (Lit), Gallons (Gal). The combination of the unit of measurement of the Partial register
and that of the Totals is predefined according to the following table:
Combination
no.
Unit of Measurement Partial Register Unit of Measurement Totals Register
1 Litres (L) Litres (L)
2 Gallons (Gal) Gallons (Gal)
3 Quarts (Qts) Gallons (Gal)
4 Pints (Pts) Gallons (Gal)
To choose between the 4 available combinations:
1
Wait for the METER to go to Standby
2
CAL
RESET
+
Then press the CAL and RESET keys together. Keep these pressed until the word
“UNIT” appears on the screen together with the unit of measurement set at that
time (in this example Litres / Litres )
3
RESET
Every short press of the RESET key, the various combinations of the units of mea-
surements are scrolled as shown below: