5 INSTALLATION
Avant-propos
K600 METER or PULSER features a 1 inch or 3/4inch inlet and outlet, depending on the
fluid for which they were calibrated, threaded and perpendicular. It is designed for fixed
in-line installation.
ATTENTION
Make sure the threaded connections do not interfere with the inside of
the measuring chamber causing the gears to seize.
Do not use any conical connections which may damage the meter body or
the connection flange.
Only the Pulser version must be connected by means of 2 cables accord-
ing to the electrical features in the diagram:
Carry out installation by placing the suction filter.
To increase the life expectancy of the liter meters it is recommended to
maintain a current value as low as possible (about 0.1 mA)
OUT
IN
AMPOLLA REED
MARRONE
BIANCO
Max Current: 0,5 mA
Max Voltage: 28 Vac/dc
Max Load 3W
Type output clean contact (open collector)
BROWN
WHITE
REED BULB
6 DAILY USE
FOREWORD
The only operations that need to be done for daily use are partial and/or resettable total
register resetting. The user should use only the dispensing system of K600. Occasionally
the meter may need to be configured or calibrated. To do so, please refer to the relevant
chapters.
PULSER VER-
SION
The pulser version of K600/3 meter when properly connected to the pulse receiver, does
not need any start/stop operation.
Below are the two typical normal operation displays. One display page shows the partial and reset total
registers. The other shows the partial and general total. Switchover from resettable total to general total
display is automatic and tied to phases and times that are in factory set and cannot be changed.
The Partial
register
Positioned in the top part of the display indicates the quantity dispensed since the
RESET key was last pressed
The RESET
Total register
Positioned in the lower part of the display, indicates the quantity dispensed since
the last RESET Total resetting. The RESET Total cannot be reset until the Partial
has been reset, while vice versa, the Partial can always be reset without resetting
the RESET Total. The unit of measurement of the two Totals can be the same as
the Partial or else different according to the factory or user settings.
The General
TOTAL register
(Total)
Can never be reset by the user. It continues to rise for the entire operating life of
the meter.