6 /20
Use, maintenance and calibration
M0147E
Main components: K600
1 - Display LCD
2 - RESET button
3 - Measuring chamber
4 - CAL button
5 - Battery housing
6 - Filter
2
4
3
1
5
6
The measurement electronics and the LCD display are fitted in the top part of the meter, isolated from the
fluid-bath measuring chamber and sealed from the outside by means of a cover.
COMPATIBLE LIQUIDS
- DIESEL FUEL at a viscosity of from 2 to 5.35 cSt (at a temperature of 37.8°C), Minimum Flash Point (PM): 55°C, according to UNI EN 590
- MOTOR OIL : SYNTHETIC / MINERAL
- PARAFFINIC DIESEL HVO & XTL (GTL/BTL/CTL/PTL) according to the EN 15940:2019
4.1 LCD DISPLAY (ONLY METER VERSION)
FOREWORD
The “LCD” of the METER features two numerical registers and various indications dis-
played to the user only when the applicable function so requires.
1
Partial register (5 figures with moving comma FROM
0.1 to 99999) indicating the volume dispensed since
the reset button was last pressed
6 Indication of type of total, (TOTAL / Reset TO-
TAL);
2 Indication of battery charge 7 Indication of unit of measurement of Totals:
L=Litres Gal=Gallons
3 Indication of calibration mode 8 Indication of Flow Rate
4 Totals register (6 figures with moving comma
FROM 0.1 to 999999), that can indicate two
types of Total:
4.1.
General Total that cannot be reset (TOTAL)
4.2. Resettable total (Reset TOTAL)
9 Indication of unit of measurement of Partial:
Qts=Quarts Pts=Pints
L=Litres Gal=Gallons
5 Indication of total multiplication factor (x10 /
x100)
4
5
6
9
7
1
2
3
Measurement
Chamber
The measuring chamber is located in the lower part of the instrument. It is fitted
with connections for the installation of threaded flanges at inlet and outlet. The
cover on the bottom part provides access to the measurement mechanism for
any cleaning operations.
Inside the measuring chamber are the oval gears which, on turning, generate
electrical pulses which are processed by the microprocessor-controlled electronic
board.
By applying a suitable calibration factor (meaning a “weight” associated with
each pulse), the microprocessor – on-board on meter versions and remote on
pulser versions - translates the pulses generated by the fluid volume rotation ex-
pressed in the set units of measurement, displayed on the partial and total reg-
isters of the LCD.