9/124
9 /20
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
translated from italian
K600
The register of
the two totals
(Reset Total
and Total)
Share the same area and digits of the display. For this reason, the two totals will
never be visible at the same time, but will always be displayed alternately.
The General
Total (Total )
Is shown during Meter standby
The Reset Total
is shown:
- At the end of a Partial reset for a certain time (a few seconds)
- During the entire dispensing stage
- For a few seconds after the end of dispensing. Once this short time has expired.
Meter switches to standby and lower register display switches to General Total
NOTE
6 digits are available for Totals, plus two icons x 10 / x100. The incre-
ment sequence is the following:
0.0 -> 99999.9 -> 999999 -> 100000 x 10 -> 999999 x 10 ->100000 x
100 -> 999999 x 100
6.1 DISPENSING IN NORMAL MODE
FOREWORD
Normal mode is the standard dispensing. While the count is made, the partial and reseable total are
displayed at the same time (reset total).
WARNING
Should one of the keys be accidentally pressed during dispensing, this
will have no effect.
STANDBY
A few seconds after dispensing has ended, on the lower register, the display switches from
resettable total to general total: the word reset above the word total disappears, and the
reset total is replaced by the general total. This situation is called standby and remains
stable until the user operates the K600 again.
6.1.1 PARTIAL RESET (NORMAL MODE)
The partial register can be reset by pressing the reset key when the meter is in stand-
by, meaning when the display screen shows the word “TOTAL”.
After pressing the reset key, during reset, the display screen first of all shows all the
lit-up digits and then all the digits that are not lit up.
At the end of the process, a display page is first of all shown with the reset partial
and the reset total
and, after a few moments, the reset total is replaced by the non resettableTotal.