20
GTEK170R
ELECTRONICS
OLED PARAMETERS
KICK IN
The trigger pulls
per second (pps)
before ramping
can start.
Available range:
3.3 - 9.9 pps
Default setting:
5.0 pps
DWELL
Solenoid
energise time in
milliseconds (ms)
for each shot.
Available range:
18.0 - 28.0 ms
Default setting:
23.0 ms
GAME TIME
Game Timer countdown clock. Can be set in 10
second increments.
Available range: 00:00 - 25:00 minutes
Default setting: 05:10 minutes
To start/stop the Game Timer press the Select
Button once. Countdown is in 1 second increments.
To reset the Game Timer back to the set value
amount, switch the marker o and on again.
DEBOUNCE
Trigger anti-bounce
settings.
(1 = lowest level
of ltering / 10 =
highest level).
Available range:
1 - 10
Default setting:
5
RESTART
The time in seconds
(s) after the last
trigger pull before
ramping can start.
Available range:
0.0 - 1.0 s
Default setting:
0.0 s