4.2.8.4 RMON Alarm
Configure RMON Alarm table on this page. The RMON Alarm screens in Figure 4-2-43 & Figure 4-2-44 appear.
Figure 4-2-43 RMON Alarm Table Page Screenshot
The page includes the following fields:
Object Description
Select Index
Select index from this drop-down list to create the new index or modify the index
Index
Indicates the index of the alarm entry
Sample Port
Select port from this drop-down list
Sample Variable
Indicates the particular variable to be sampled, the possible variables are:
DropEvents: The total number of events in which packets were dropped due
to lack of resources.
Octets: The number of received and transmitted (good and bad) bytes.
Includes FCS, but excludes framing bits.
Pkts: The total number of frames (bad, broadcast and multicast) received
and transmitted.
BroadcastPkts: The total number of good frames received that were
directed to the broadcast address. Note that this does not include multicast