10. Connection to the power supply
10.1 General
Attention!
GERMANY: The conditions for connecting the electrofusion control unit in this instruction manual,
the technical connection regulations of the local power supply company, the VDE regulations, the
regulations for accident prevention as well as other DIN/CEN
regulations in force must always be
observed.
OTHER COUNTRIES: It is mandatory to observe the connection regulations for the electrofusion
control unit in this instruction manual as well as all international and national health and safety
regulations and the respective technical connection regulations in force.
Electrofusion control units may only be used by trained and, according to national and international
standards, certified personnel.
The user must supervise and observe the electrofusion control unit
welding procedure.
The electrofusion control unit must only be operated within the following operation ranges:
230 V devices 110 V devices
Minimum Fuse/
Circuit breaker rating
Attention!
• Operation of the electrofusion control unit is only allowed if a properly dimensioned and intact
RCD is used. The information for proper fuse protection in the circuit are shown in the table
above.
• The electrofusion control unit's mains supply cord as well as any extension cords must be fully