10.2 Extension cables
Attention!
• The extension cords must provide a protective earthing contact.
• It is forbidden to extend the welding cable.
•
Always observe all international and national legislation and guidelines for extending
mains supply cords.
10.2.1 General
The mains supply cord shall only be extended in accordance with the following specifications.
Cable length Cross Section (230 V) Cross Section (110 V)
10.2.2 For Australia
The mains supply cord must only be extended using approved extension cords These can be obtained on
request from your local distributor of electrofusion control boxes made by PF-Schweißtechnologie GmbH.
Attention!
•
For electrofusion control boxes used in Australia only extension cords acknowledged
and approved by PF-
Schweißtechnologie GmbH, a local distributor or an official PF
service station shall be used.
• Using a non-approved extension cord is a health safety risk.
•
Using a non-approved extension cord voids the manufacturer's warranty on the unit.