6.1 DC Voltage
Range
Accuracy
600 mV
± (0.5% + 5)
6 V
60 V
600 V
Input resistance: 10
Maximum input voltage: 600 V
6.2 AC Voltage
Range
Accuracy
600 mV
± (1% + 4)
6 V
60 V
600 V
Input resistance: 10
Maximum input voltage: 600 V
Frequency response: 10 Hz to 1 kHz, TRMS
6.3 Resistance
Range
Accuracy
600 Ω
±(0.8% readings + 5 digits)
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ
Overload protection: 250 V DC/AC
Open circuit voltage: 2.4 V
6.4 Diode and Buzzer Test
The display shows the forward voltage drop
It buzzes when the resistor is less than 30 and the indicator lights
Overload protection: 250 V DC/AC