Before opening the case or the battery cover, the meter and input signal must be turned off to avoid
electric shock or damage to the instrument.
In general, if something unusual happens or if you suspect that something is wrong or has
malfunctioned, do not do anything with the product and immediately contact the seller for assistance
(email address: office@plusivo.com)
4. Technical Specifications
Environmental conditions of use:
CAT. III 600 V
Pollution level: 2
Altitude < 2000 m
Working environment temperature and humidity:
0~40°C (<80% RH, <10°C non condensing)
Storage environment temperature and humidity:
-10~60°C (<70% RH,remove the battery)
Temperature coefficient: 0.1 x accuracy/°C (<18°C or >28°C)
MAX. Voltage between terminals and earth ground: 600 V
Fuse protection: mA: F600 mA/250 V fuse, 10 A: F10 A/250 V fuse
Conversion rate: 3s/second
Test or calibrate surrounding temperature: 20°C±2°C
Sampling rate: about 3 times/second
Display: 6000 counts LCD display with LED backlight. Automatically displays the unit symbols
according to the shift of the measurement function.
Over range indication: it displays "OL".
Low battery indication: when the battery voltage is lower than the normal working voltage " "
will be displayed.
Input polarity indication: automatically displays " - ".
Power requirement: 3 x 1.5 V AAA batteries.
Dimension: 147 mm (L) x 71 mm (W) x 45 mm (H).
Weight: about 220g (battery excluded)
7
Mastering the Art of Measurement (DM501D Digital Multimeter) r.01 www.plusivo.com