When set to "1", the system creates security log entries when it detects a possible network
intrusion.
0 (default)
1
sec.telnet.apiPort
Specifies whether to use port 23 or 24 for command-line API access.
24 (default)
23
sec.telnet.apiPortIdleTimeout.enable
Specifies whether to allow the command-line API port to time out at the configured time interval
or not.
The timeout is set using sec.web.idleSessionTimeout.
0 (default)
1
sec.telnet.diagPortIdleTimeout.enable
Specifies whether to allow the diagnostics port to time out at the configured time interval or not.
The timeout is set using sec.web.idleSessionTimeout.
0 (default)
1
sec.telnet.enable
Specifies whether you can access the system using telnet.
0 (default)
1
sec.web.enable
Specifies whether you can access the system using its web interface.
1 (default)
0
sec.web.httpsOnly
Specifies that the system web interface is accessible only over port 443. Setting this to "1"
closes access through port 80 (HTTP).
0 (default)
1
sec.web.idleSessionTimeout
Specifies the number of minutes a session can be idle before it times out.
1
3
5
10 (default)
Security Parameters