Chapter 3 - System Commands
© Polycom, Inc. 3 - 75
prilinebuild-
out
prilinebuildout <set|get> <“attenua-
tion in dB”|“attenuation in feet”>
Where:
set: Sets the PRI line buildout. It
requires an output “attenuation in
dB” or an “attenuation in feet”.
•get: Returns the current setting.
“attenuation in dB”: Output
attenuation values in dB. For internal
CSUs. Available values are
0
-7.5
-15
-22.5
“attenuation in feet”: Output
attenuation values in feet. For
external CSUs. Available values are:
0-133
134-266
267-399
400-533
534-665
Sets or gets the PRI line
buildout for a T1 interface. If you
are using an internal CSU, enter
the output attenuation in dB. If
you are using an external CSU,
enter the output attenuation in
feet.
User interface screen location:
System > Admin Settings >
Network > IDSN (page 3): Line
Build Out
prilinebuildout
set -7.5
Command Syntax Description Example