Integrator's Reference Manual for the VSX Series
3 - 100 www.polycom.com/videodocumentation
popupinfo
popupinfo <register|unregister>
Where:
•register: Registers to receive popup
information.
•unregister: Unregisters to receive
popup information.
Registers or unregisters to
receive popup text and button
choices text.
popupinfo
register
later returns something
like this if a call fails:
popupinfo: ques-
tion: Sorry.
Cannot dial number
because you are
already in a call
with the site.
popupinfo:
choice0: Ok
or if the user edits the
password field, the API
feedback is:
popupinfo: ques-
tion: Save
Changes?
popupinfo:
choice0: Yes
popupinfo:
choice1: No
popupinfo:
answered: Yes
rs232 baud rs232 baud
<1200|2400|9600|14400|19200|38400
|57600|115200|get>
Where:
9600, 14400, 19200, 38400, 57600,
115200: Sets the RS-232 port to this
baud rate.
get: Returns the current baud rate
setting.
Configures the RS-232 port
baud rate.
User interface screen location:
System > Admin Settings >
General Settings > Serial
Port: Baud Rate
rs232 baud 9600
Command Syntax Description Example