EasyManua.ls Logo

POOL LAB PL35 - DIAGNOSTIC MESSAGES; CHECK SALT; CHECK SALT CELL OFF; HIGH SALT

POOL LAB PL35
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIAGNOSTIC MESSAGES
Diagnostic messages will be displayed on the bottom line of the LCD when in HOME
VIEW. The messages and their meanings are explained below, with some basic tips to
rectify the issue if necessary. If the problem persists, consult the troubleshooting guide for
more information.
CHECK SALT
The system has detected unusually low conductivity in the cell, possibly due to a low salt
level, and is running inefficiently. The system will continue to run as normal, but may not
be able to produce chlorine to its full potential. This can also be caused by very cold
water, in which case the message can generally be ignored.
Check the salt level, and add salt if required
Inspect the cell for debris or calcium scale
CHECK SALT CELL OFF
The system has detected critically low conductivity in the cell, possible due to a very low
salt level. Power to the cell has been turned off to prevent damage. The filtration system
will run as normal, but no chlorine will be produced. Once every five minutes, the system
will re-check and resume normally if the condition is rectified.
Check the salt level, and add salt if required
Inspect the cell for debris or calcium scale
HIGH SALT
The system has detected unusually high conductivity in the cell, possibly due to a high salt
level. Usually no user action is required, this is just a warning not to add any more salt.
Chlorine can still be produced efficiently, but it is nearing the threshold where it could
trigger HIGH SALT CELL OFF. This message is more likely to appear at higher water
temperatures.
Check the salt level, and top up the pool with fresh water if possible
DO NOT ADD SALT
HIGH SALT CELL OFF
The system has detected critically high conductivity in the cell, possibly due to a very high
salt level, or a combination of high salt and high water temperatures. Power to the cell has
been turned off to prevent damage. The filtration system will continue to run as normal,
but no chlorine will be produced. Once every five minutes, the system will re-check and
resume normally if the condition is rectified.
Check the salt level, and top up the pool with fresh water if possible
DO NOT ADD SALT
If the salt level is significantly too high, it may be necessary to drain some water and
top up with fresh water.
18

Table of Contents