8 | EN
At recepon, please check that your package contains the following:
• A Poolex heat pump
• 2x 1"1/2 (inch) to DN48.3 hydraulic connections
• 1x spa heater control relay
• 4x an-vibraon pads (directly mounted on the heat pump)
• Drainage kit
• This installaon and operaon manual
2. DESCRIPTION
2.1 Package contents
Air
(1)
15°C
Water
(2)
26°C
Heating power (kW) 2.02 - 5.04
Consumption (kW) 0.27 - 1.18
COP (Coe. of performance) 7.48 - 4.26
Air
(1)
26°C
Water
(2)
26°C
Heating power (kW) 2.75 – 6.84
Consumption (kW) 0.22 – 1.18
COP (Coe. of performance) 12.5 – 5.78
Air
(1)
35°C
Water
(2)
27°C
Cooling capacity (kW) 1.5 – 3.14
Consumption (kW) 0.30 – 1.08
EER 5.0 – 2.9
Power supply Single phase 220-240Vac ~ 50Hz
Maximum power
2.0 kW
Maximum current 9 A
Heating temperature range (water temperature) 15°C ~ 40°C
Operating range (ambiant air temperature) - 20°C ~ 40°C
Unit dimensions L×P×H (mm) 750 x 460 x 460 mm
Unit weight (kg) 38 kg
Sound pressure level 10 m (dBA)
(3)
< 33
Hydraulic connections (mm) D50
Heat exchanger PVC tank and tianium heating coil
Advised water ow (m³/h) 2.0 m³/h
Compressor type Rotary
Refrigerant / Loaded volume (kg) R32 / 0.4 kg
Protection rating IPX4
Load loss (mCE) 1.2
Control panel Digital and Wi
Modes Heating and cooling
The technical specicaons of our heat pumps are provided for informaon purposes only. We reserve the right
to make changes without prior noce.
1
Ambient air temperature
2
Inial water temperature
3
Noise level at a distance of 10 m in accordance with internaonal standards EN ISO 3741 and EN ISO 354
2.2 Characteristics