10 | EN
>2.5m
The heat pump must be installed at least 2.5 m away from the pool.
SPA
Please respect the following rules when choosing the heat pump’s installaon locaon
1. The locaon must be easily accessible for opmal operaon and maintenance.
2. The device must be installed on the ground, ideally on a level concrete slab. Ensure that the
ground is suciently stable and it can support the weight of the device.
3. Check that there is enough air ow, that the air exhaust is not directed towards the windows
of neighbouring buildings, and that exhaust air cannot return to the intake. In addion,
ensure that there is enough space around the device to perform servicing and maintenance.
4. The device must not be installed in locaons suscepble of being exposed to oil, ammable
gas, corrosive agents, sulphur compounds, or near high frequency devices.
5. Do not install the device near to roads or footpaths to avoid mud splaering.
6. To avoid disturbing neighbours, make sure to install the device facing away from areas sen-
sive to noise.
7. Keep out of the reach of children insofar as possible.
3. INSTALLATION
To install the heat pump only the hydraulic circuit and the power need to be connected.
Do not place anything within 2.50 m of the front of the heat pump.
Leave at least 30cm of empty space to the sides and rear of the heat pump.
Do not place any obstacles on top or in front of the device!
3.1 Location