Storage Temperature Recharge Frequency Charging Duration
-25°C - 40°C Every 3 months 1-2 hours
40°C - 45°C Every 2 months 1-2 hours
1 IMPORTANT SAFETY WARNING continued
STORAGE
Before storing, charge the UPS 6 hours. Store the UPS covered and upright in a cool, dry
location. During storage, recharge the battery in accordance with the following table:
SAFETY CAUTION
Please read carefully the following safety instructions before using the Commander UPS.
SAFETY INSTRUCTION WARNING
This is a category C2 UPS product. In a residential environment, this product may cause
radio interference, in which case the user may be required to take additional measures.
CAUTION
A) The mains socket outlet that supplies the UPS shall be installed near the UPS and
shall be easily accessible.
B) Please replace the fuse or circuit breaker only with the same type and amperage in
order to avoid fire hazards.
C) CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
D) When replacing batteries, replace with the same type and number of batteries or
battery packs.
E Servicing of batteries should be performed or supervised by personnel
knowledgeable about batteries and the required precautions.
F CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
G) CAUTION: Do not open or mutilate batteries. Released electrolyte is harmful to the
skin and eyes. It may be toxic.
6